Detached house Otelfingen ZH

Four years of renovation.

Between 2015 and 2018 the owner renewed the house step by step, from the heating and the envelope to the lower floor and the roof with solar system. The list follows the construction accounts.

← Back to the property page
327'757francs invested between 2015 and 2018
318'285francs after deducting subsidies received
6'953 kWhsolar power per year on average, measured 2019 to 2024
Chronology

What was done and when.

The amounts are the actual final amounts according to the construction accounts. The owner's own work is not included, nor are quotes or budget figures.

2015Heating replaced by air-to-water heat pumpStiebel Eltron WPL 25 as a split unit, new radiators on both floors with electronic thermostats, electrical connection, base for the outdoor unit, new stairs with railing and waste pipe57'889.55
2015Attic insulatedBlown-in insulation, around 80 m²4'233.04
2015/16South and west facades insulated, pergola replacedExternal insulation with render, scaffolding, new pergola, blinds on the east facade, sheet-metal work, ventilation with heat recovery in the bathroom, east side redesigned with retaining wall and stairs, surroundings restored45'127.70
2016/17Lower floor renovated, building services renewedDamp remediation with internal insulation, cellar insulation, insulated doors and front door, new windows, drains under the house renovated, new house connection, new main electrical distribution with installations, heating, plumbing and ventilation, bathroom, screed, stairs renovated, sun blinds in the living room122'955.81
2016Garden and entranceNew garden stairs with railing, water tank in the entrance area18'450.19
2015 to 2017Planning, permits and feesPlanning and building application, surveyor, energy certificate, asbestos check, insurance, fees19'809.74
2018Roof replaced, 7.5 kWp solar systemPhotovoltaic system with electrical work, roofing, scaffolding, sheet-metal work, fees50'431.56
2018West facade and porchFacade construction and painting8'859.90
Total investments in francsCHF 327'757.49
2017/18Subsidies receivedBuilding services and insulation CHF 4'560.00, solar system CHF 4'912.00-9'472.00
Investments after subsidiesCHF 318'285.49
Before 2015

What the previous owner renewed.

Between 1998 and 2006 the ground floor was renewed in stages. The amounts come from invoices and order confirmations, each including VAT.

1998Windows, first halfRenovation windows wood/metal, 4B aluba, according to the order confirmation11'093.95
2002Balcony newly builtSteel structure with stainless-steel railing and wooden floor, masonry, blinds29'089.90
2004Bathroom renovatedNew sanitary fittings, building work30'689.55
2005Parquet laidBeech in the living room, corridor and entrance, with impact sound insulation6'771.65
2006Kitchen replacedFitted kitchen with granite worktop and appliances according to the order confirmation, electrical work28'926.00
Renovations 1998 to 2006CHF 106'571.05

In addition, according to the owner, painting work on the ground floor in 2024. According to the owner, all windows have been replaced and the ceramic tiles in the kitchen laid; there are no invoices for this, so they are listed without an amount. After 2022 the drains were renovated again up to the connection, also without an amount in this list.

Solar power

What the system delivers.

The solar system has been running since September 2018. The owner reads the meters monthly. The values are full calendar years in kWh.

2019System productionHouse consumption 5'364, drawn from the grid 4'099, fed into the grid 6'0987'363 kWh
2020System productionHouse consumption 5'637, drawn from the grid 4'134, fed into the grid 6'0177'520 kWh
2021System productionHouse consumption 5'959, drawn from the grid 4'509, fed into the grid 5'4596'909 kWh
2022System productionHouse consumption 4'351, drawn from the grid 3'229, fed into the grid 6'3397'461 kWh
2023System productionHouse consumption 3'640, drawn from the grid 2'856, fed into the grid 5'7656'549 kWh
2024System productionHouse consumption 3'009, drawn from the grid 2'460, fed into the grid 5'3665'916 kWh
Average 2019 to 2024House consumption 4'660, drawn from the grid 3'548, fed into the grid 5'8416'953 kWh

Receipts

The invoices from 1998 to 2006, the construction accounts from 2015 to 2017 and from 2018, and the solar system's meter readings are available. Prospective buyers and their bank can view them at our office.

Sources: invoices and order confirmations of the previous owner (1998 to 2006), construction accounts of the owner (2015 to 2017 and 2018), monthly evaluation of the solar system 2018 to 2024. Information without guarantee; the original documents and the purchase contract are authoritative.